Doc# E149701 B - 29
B: Modbus Map and Retrieving Logs
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
2 COM 2 (RS485)
3 COM 3 (Option Card 1)
4 COM 4 (Option Card 2)
7 User (Face Plate)
Param 1-4: These are defined for each event (see table below).
NOTE: The System Log Record is 20 bytes, consisting of the Record Header (12
bytes) and Payload (8 bytes). The Timestamp (6 bytes) is in the header. Typically,
software will retrieve only the timestamp and payload, yielding a 14-byte record. The
table below shows all defined payloads.
Group
(Event
group)
Event
(Event
within
group)
Mod
(Event
modifier)
Channel
(1-4 for
COMs, 7
for USER,
0 for FW)
Parm1 Parm2 Parm3 Parm4 Comments
0 Startup
000FW version Meter Run
Firmware
Startup
1slot#0class IDcard
status
0xFF 0xFF Option Card
Using Default
Settings
1 Log Activity
1 log# 1-4 0xFF 0xFF 0xFF 0xFF Reset
2 log# 1-4 0xFF 0xFF 0xFF 0xFF Log Retrieval
Begin
3 log# 0-4 0xFF 0xFF 0xFF 0xFF Log Retrieval
End
2 Clock Activity
1 0 1-4 0xFF 0xFF 0xFF 0xFF Clock Changed
2000xFF0xFF0xFF0xFFDaylight Time
On
3000xFF0xFF0xFF0xFFDaylight Time
Off
3 System Resets