1. INP100S: 100BaseT Ethernet Capability
The meter can provide 100BaseT Ethernet functionality.
• Embedded web server
• Network Time Protocol (NTP) support (Network Clock Sync)
• 12 simultaneous Modbus TCP/IP connections
• 5 simultaneous DNP over TCP/IP connections
• Dual Ethernet Ports available
2. 1mAOS: Four Channel Bi-directional 0-1mA Outputs
• Assignable to any parameter
• 0.1% of full scale
• 0 to 10K Ohms
• Range +/- 1.20mA
• Designed for RTUs and generating stations
3. 20mAOS: Four Channel 4-20mA Outputs
• Assignable to any parameter
• 0.1% of full scale
• 0 to 850 Ohms at 24VDC
• Loop Powered using up to 24 Volts DC
• Ideal for any Process Control application
4. RO1S: Two Relay Outputs / Two Status Inputs
• 250VAC/30VDC - 5A Relays, Form C
• Trigger on user set alarms
• Set delays and reset delays
• Status Inputs – Wet / Dry Auto Detect (Up to 150 VDC)
• Must be used with V4 or higher V-Switch™ option for
limit based alarms and control
• Allows for control, alarm and status
5. PO1S: Four Pulse Outputs / Four Status Inputs
• Programmable to any energy parameter and pulse value
• Form A: Normally open contacts
• Also used for End of Interval pulse
• Can function for manual relay control and limit
based control (V4-V6 Options)
• 120mA continuous load current
• Status Inputs - Wet / Dry Auto Detect (Up to 150 VDC)
• Provides KYZ outputs and pulse input counting
6. FOVPS or FOSTS: Fiber Optic Card
• EIG’s exclusive Fiber Optic Daisy Chain switchable
built-in logic mimics RS485 half duplex bus, allowing
you to daisy chain meters for lower installation costs.
Full duplex is also assignable.
• ST Terminated Option (-FOSTS)
• Versatile Link Terminated Option (-FOVPS)
• Modbus and DNP 3.0 protocols available
• The preferred communication method for intrinsic safety
and high reliability
STANDARD COMMUNICATION CAPABILITY
Field Expandable I/O Slots
Simple
Field
Upgrade
Meter Auto Detects I/O Card Type
The Shark® 200 meter offers unequaled I/O expandability. Using the two universal option slots, the unit can be easily configured to accept
new I/O cards even after installation. The unit auto-detects installed I/O option cards. Up to 2 cards of any type can be used per meter.
Note: I/O cards can be ordered separately - see last page.
The Shark® 200 meter provides two independent communication
ports with advanced features.
Rear Mounted Serial Port with KYZ Pulse
• RS485 - This port allows RS485 communication using Modbus
or DNP 3.0 Protocols. Baud rates are from 1200 to 57600.
• KYZ Pulse - In addition to the RS485, the meter also
includes Pulse Outputs mapped to absolute energy.
Front Mounted IrDA Communication
Uniquely, the Shark® 200 meter also has an optical IrDA port,
allowing you to program it with an IrDA-enabled laptop PC.
FIELD EXPANDABLE I/O AND COMMUNICATION CAPABILITIES